Model
|
Supply Air
Flow Rate L/min(ANR) (scfm) |
Dimensions
mm (inch) |
Connector Size
|
Weight
kgf (lbs) |
Purging
System |
|||
|---|---|---|---|---|---|---|---|---|
|
Supply
Gas Inlet/Outlet |
Purging
Gas Inlet/Outlet |
|||||||
| SWB-01-100 |
∼150
(∼5.3) |
Dia=32
(1.3) |
-
|
L=240
(9.4) |
Rc1/4
(NPT1/4) |
Rc1/8
(NPT1/8) |
0.22
(0.49) |
-
|
| SWB-01-200 |
∼100
(∼3.5) |
Dia=32
(1.3) |
-
|
L=340
(13.4) |
0.26
(0.57) |
-
|
||
| SWB-02-100 |
∼300
(∼10.6 |
Dia=50
(2.0) |
-
|
L=310
(12.2) |
Rc3/8
(NPT3/8) |
Rc1/2
(NPT1/2) |
0.63
(1.39) |
-
|
| SWB-05-100 |
∼600
(∼21.2) |
0.66
(1.46) |
-
|
|||||
| SWB-10-150 |
∼1200
(∼42.4) |
Dia=75
(3.0) |
-
|
L=340
(13.4) |
Rc1/2
(NPT1/2) |
-
|
1.32
(2.91) |
(*2)
|
| SWB-17-200 |
∼1800
(∼63.6) |
Dia=110
(4.3) |
-
|
L=370
(14.6) |
Rc1
(NPT1) |
-
|
4.81
(10.6) |
|
| SWC-M04-70/OP |
∼15
(∼0.5) |
W=36
(1.4) |
H=75
(3.0) |
D=15
(0.6) |
M5
(Female) |
M5
(Female) |
0.05
(0.11) |
-
|
| SWC-M04-70/IP |
-
|
(*2)
|
||||||
| SWC-M08-100 |
∼50
(∼1.8) |
W=61
(2.4) |
H=112
(4.4) |
D=31
(1.2) |
Rc1/8
(NPT1/8) |
-
|
0.26
(0.58) |
(*2)
|
| SWC-M08-100/H (*1) |
||||||||
| SWC-M15-100 |
∼80
(∼2.8) |
W=61
(2.4) |
H=112
(4.4) |
D=31
(1.2) |
Rc1/8
(NPT1/8) |
-
|
0.27
(0.60) |
(*2)
|
| SWC-M15-100/H (*1) |
||||||||
| SWC-01-150 |
∼150
(∼5.3) |
W=70
(2.8) |
H=150
(5.9) |
D=40
(1.6) |
Rc1/4
(NPT1/4) |
-
|
0.39
(0.86) |
(*2)
|
| SWC-02-250 |
∼300
(∼10.6) |
W=100
(3.9) |
H=200
(7.9) |
D=50
(2.0) |
Rc3/8
(NPT3/8) |
-
|
0.69
(1.53) |
(*2)
|
| SWC-03-250 |
∼450
(∼15.9) |
W=100
(3.9) |
H=200
(7.9) |
D=50
(2.0) |
Rc3/8
(NPT3/8) |
-
|
0.71
(1.57) |
(*2)
|
| SWC-03-250/H (*1) |
||||||||
| SWF-M06-400 (*3) |
∼30
(∼1.1) |
Dia=25
(1.0) |
-
|
L=516
(20.3) |
Rc1/4
(NPT1/4) |
Rc1/8
(NPT1/8) |
0.12
(0.26) |
-
|
(*1)These are the product of a low purge gas flow type.
(*2)These are equipped with built-in purging circuits, allowing ease of use without the purging line outside the unit.
(*3)Model : SWF-M06-400
Since the casing is constructed with a flexible material, the middle part of the casing can be bent into a U-shape with a minimum inner radius of curvature of 35mm(1.4 inch), thus allowing installation in a narrow space.
|
Use and
Applicable Fluid |
Dehumidification of Compressed
Non-Corrosive Gas |
Notes
|
|
|---|---|---|---|
|
Fluid Temp.
[min. ∼max.] |
-4 ∼ +131°F
(Not frozen) -20 ∼ +55℃ |
To maintain satisfactory dehumidifying performance, we recommend use at a lower Tin value and within the following range; |Tin-Tamb| ≤ 41°F |Tin-Tamb| ≤ 5°C |
|
|
Ambient Temp
. [min. ∼max.] |
-4 ∼ +131°F
(Not frozen) -20 ∼ +55 °C |
||
|
Pressure Range.
[min. ∼max.] |
Compressed Gas Inlet to Outlet : 0∼0.85MPa( Gauge) | ||
| Purging Gas Inlet to Outlet : 0∼0.05MPa(Gauge) | |||
⇒【SWG Series Standard Specifications】
|
|
MPa (Gauge)
[psig] |
||||||
|---|---|---|---|---|---|---|---|
|
Model
|
Switch
dial Position *2 |
0.3
[43] |
0.5
[71] |
0.7
[100] |
|||
|
Purging Air Flow Rate
|
|||||||
|
No.
|
L/min
(ANR) |
scfm
|
L/min
(ANR) |
scfm
|
L/min
(ANR) |
scfm
|
|
| SWB-10-150 | - | 80 | 2.82 | 120 | 4.24 | 150 | 5.65 |
| SWB-17-200 | - | 136 | 4.80 | 203 | 7.17 | 270 | 953 |
| SWC-M04-70/IP | - | 1 | 0.04 | 1.5 | 0.05 | 2 | 0.07 |
| SWC-M08-100 | - | 3 | 0.11 | 5 | 0.18 | 6 | 0.21 |
| SWC-M08-100/H *1 | - | 1.5 | 0.05 | 2 | 0.07 | 3 | 0.11 |
| SWC-M15-100 | - | 6 | 0.21 | 9 | 0.32 | 12 | 0.42 |
| SWC-M15-100/H *1 | - | 3 | 0.11 | 5 | 0.18 | 6 | 0.21 |
| SWC-01-150 | 1 | 3 | 0.11 | 5 | 0.18 | 6 | 0.21 |
| 2 | 6 | 0.21 | 9 | 0.32 | 12 | 0.42 | |
| 3 | 12 | 0.42 | 19 | 0.67 | 25 | 0.88 | |
| SWC-02-250 | 1 | 12 | 0.42 | 19 | 0.67 | 25 | 0.88 |
| 2 | 25 | 0.88 | 38 | 1.34 | 50 | 1.77 | |
| 3 | 37 | 1.31 | 56 | 1.98 | 75 | 2.65 | |
| SWC-03-250 | 1 | 25 | 0.88 | 38 | 1.34 | 50 | 1.77 |
| 2 | 37 | 1.31 | 56 | 1.98 | 75 | 2.65 | |
| 3 | 63 | 2.22 | 94 | 3.32 | 125 | 4.41 | |
| SWC-03-250/H *1 | 1 | 12 | 0.42 | 19 | 0.67 | 25 | 0.88 |
| 2 | 25 | 0.88 | 38 | 1.34 | 50 | 1.77 | |
| 3 | 37 | 1.31 | 56 | 1.98 | 75 | 2.65 | |
*1 These product are low purge type.
*2 SWC-01-150、SWC-02-250、SWC-03-250、SWC-03-250/H
have Dial to control flow rate of Purging Gas.
When specifications and on OEM contact are required, please feel free to consult with us.